Skip to content
Copper Tubes & Coils for HVAC Applications

Products

We offer a comprehensive range of copper products designed for air conditioning and refrigeration systems, including:

Copper Coils

Copper Coils

Soft annealed ACR coils supplied in 15 m lengths for air conditioning and refrigeration installations.

Contact Sales Copper Coils
Thermal Insulation

Protect every line you install

Alongside our copper range we supply GoFlex flexible elastomeric insulation, to cut energy loss and stop condensation on HVAC&R pipework.

GoFlex black elastomeric foam insulation tubesGoFlex

GoFlexFlexible Elastomeric Thermal Insulation

The ideal insulation for VRV/VRF systems

Massive cost savings by using GoFlex to reduce energy loss and prevent condensation.

Thermal conductivity
0.035 W/(m·K)
Line temperature
-40 °C → 105 °C
Fire rating · BS 476 Part 7
Class 1
Density
40–70 kg/m³

Manufactured by Hira Industries — United Arab Emirates

Available Sizes

A complete range of standard copper tube sizes

Saudi Master Copper supplies a complete range of standard copper tube sizes.

Suitable for:

  • Split Air Conditioning Systems
  • Central Air Conditioning Systems
  • Chillers
  • Refrigeration Systems
  • Residential Projects
  • Commercial Buildings
  • Industrial Facilities

Technical Specifications

Standard sizes, wall thicknesses and weights for our copper tube ranges.

Soft Coil

For Air Conditioning and Refrigeration

Length:15 mCertified Pressure:700 PsiTemper Quality:O60

Soft Coil ACR Type LStandardASTM B280

ODWall ThicknessWeight
inchmminchmmkg/mlb/ft
1/46.350.030.7620.120.08
5/167.940.0320.8130.1630.109
3/89.530.0320.8130.1990.134
1/212.70.0320.8130.2710.182
5/815.880.0350.8890.3740.251
3/419.050.0350.8890.4530.305
7/822.230.0451.1430.6770.455

Soft Coil ACR Type LEconomyASTM B743

ODWall ThicknessWeight
inchmminchmmkg/mlb/ft
1/46.350.0240.610.0980.066
5/167.940.0240.610.1260.084
3/89.530.0240.610.1530.103
1/212.70.0280.7110.2390.161
5/815.880.0280.7110.3030.204
3/419.050.0320.8130.4160.28
7/822.230.0350.8890.5320.378

Soft Coil ACR Type KStandardASTM B280

ODWall ThicknessWeight
inchmminchmmkg/mlb/ft
3/89.530.0350.8890.2160.145
1/212.70.0491.2450.40.269
5/815.880.0491.2450.5120.344
3/419.050.0491.2450.6220.418
7/822.230.0651.6510.9540.641

Straight Hard Pipe

For Air Conditioning and Refrigeration

Length:6 mCertified Pressure:700 PsiTemper Quality:H58

Straight Tubes Type LStandardASTM B280

ODWall ThicknessWeight
inchmminchmmkg/mlb/ft
3/89.530.0320.8130.1990.134
1/212.70.0350.8890.2950.198
5/815.880.041.0160.4240.285
3/419.050.0421.0670.5390.362
7/822.230.0451.1430.6770.455
1 1/828.580.051.270.9740.654
1 3/834.930.0551.3971.3150.884
1 5/841.280.061.5241.7011.143
2 1/853.980.071.7782.6061.751
2 5/866.680.082.0323.6892.479
3 1/879.380.092.2864.9493.325
3 5/892.080.12.546.3864.291
4 1/8104.780.112.7948.0015.377

Straight Tubes Type KStandardASTM B280

ODWall ThicknessWeight
inchmminchmmkg/mlb/ft
3/89.530.0350.8890.2160.145
1/212.70.0491.2450.40.269
5/815.880.0491.2450.5120.344
3/419.050.0491.2450.6220.418
7/822.230.0651.6510.9540.641
1 1/828.580.0651.6511.2480.839
1 3/834.930.0651.6511.5431.037
1 5/841.280.0721.8292.0261.361
2 1/853.980.0832.1083.072.063
2 5/866.680.0952.4134.3552.926
3 1/879.380.1092.7695.9574.003
3 5/892.080.123.0487.625.12
4 1/8104.780.1343.4049.696.511

Straight Hard Tube

For Water

Length:6 mCertified Pressure:700 PsiStandard:ASTM B88Temper Quality:O60 / H58

Straight Tubes Type KASTM B88

Pipe SizeWall Thickness
NominalOD (inch)OD (mm)inchmm
1/43/89.530.0350.889
3/81/212.70.0491.245
1/25/815.880.0491.245
5/83/419.050.0491.245
3/47/822.230.0651.651
11 1/828.580.0651.651
1 1/41 3/834.930.0651.651
1 1/21 5/841.280.0721.829
22 1/853.980.0832.108
2 1/22 5/866.680.0952.413
33 1/879.380.1092.769
3 1/23 5/892.080.123.048
44 1/8104.780.1343.404

Straight Tubes Type LASTM B88

Pipe SizeWall Thickness
NominalOD (inch)OD (mm)inchmm
1/43/89.530.030.762
3/81/212.70.0350.889
1/25/815.880.041.016
5/83/419.050.0421.067
3/47/822.230.0451.143
11 1/828.580.051.27
1 1/41 3/834.930.0551.397
1 1/21 5/841.280.061.524
22 1/853.980.071.778
2 1/22 5/866.680.082.032
33 1/879.380.092.286
3 1/23 5/892.080.12.54
44 1/8104.780.112.794

Straight Tubes Type MASTM B88

Pipe SizeWall Thickness
NominalOD (inch)OD (mm)inchmm
3/81/212.70.0250.635
1/25/815.880.0280.711
3/47/822.230.0320.813
11 1/828.580.0350.889
1 1/41 3/834.930.0421.067
1 1/21 5/841.280.0491.245
22 1/853.980.0581.473
2 1/22 5/866.680.0651.651
33 1/879.380.0721.829
3 1/23 5/892.080.0832.108
44 1/8104.780.0952.413

Straight Hard Tube

For Medical Gas Systems

Length:6 mCertified Pressure:700 PsiStandard:ASTM B819Temper Quality:H58
Pipe SizeK-TypeL-Type
NominalOD (inch)OD (mm)inchmminchmm
1/43/89.530.0350.8890.030.762
3/81/212.70.0491.2450.0350.889
1/25/815.880.0491.2450.041.016
5/83/419.050.0491.2450.0421.067
3/47/822.230.0651.6510.0451.143
11 1/828.580.0651.6510.051.27
1 1/41 3/834.930.0651.6510.0551.397
1 1/21 5/841.280.0721.8290.061.524
22 1/853.980.0832.1080.071.778
2 1/22 5/866.680.0952.4130.082.032
33 1/879.380.1092.7690.092.286
3 1/23 5/892.080.123.0480.12.54
44 1/8104.780.1343.4040.112.794

Copper Drainage Tube (DWV)

Straight Tube

Length:6 mStandard:ASTM B306
Pipe SizeWall Thickness
NominalOD (inch)OD (mm)inchmm
1 1/41 3/834.930.041.02
1 1/21 5/841.280.0421.07
22 1/853.980.0421.07
33 1/879.380.0451.14
44 1/8104.780.0581.47

Plain Level Wound Coil

LWC

Standard:ASTM B734
Alloys

DHP (C12200) — High Phosphorus

DLP (C12000) — Low Phosphorus

Tempers
H / OL / O
OD Range
3/16" – 7/8" (4.76 – 22.23 mm)

Full size charts are available on request.

Let's talk about your project